Resumen de los elementos de Programación (Software) EX2000

Slides:



Advertisements
Presentaciones similares
Mr. Redaelli OnlineTaco.com. To Have - Tener Yo tengo – I have Tú tienes – You have (Informal) Usted tiene – You have (Formal) El tiene – He has Ella.
Advertisements

2003 HYPACK MAX Training Seminar1 77 – Digitizing Chart Data to DGW Format El programa del MAPA se usa para digitalizar la información del mapa náutica.
Game Cluedo: How to Play 1.Your group should have the 21 cards containing 6 cards of suspects, 9 rooms and 6 weapons, a tally card for each member and.
Isn’t so bad when you get the hang of it!  The verbs we learned in Chapter 1 were in the infinitive form.  That means their English translation would.
Negatives and Questions. Negatives Consider the following sentences: Juan estudia mucho. Marta y Antonio viven en Georgia. Rita y el chico necesitan.
WALT: talking about dates and saying when your birthday is WILF: To be able to write & understand months and dates in Spanish to get to a Level 2 To be.
Dónde vs. Adónde Dónde means WHERE. When dónde is used, it is usually in relation to where someone IS LOCATED RIGHT THEN. Ex: ¿Dónde estás tú? Yo estoy.
Irregular Preterite IR and SER Both verbs conjugate the same in preterite tense… so how can you tell them apart?
How to Conjugate Regular –AR Verbs in the Present Tense.
Objectivos de esta leccion: Usar los pronombres indirectos correctamente Usar los pronombres directos correctamente Usar los pronombres dobles correctamente.
Tecnología y Estructura de Costos. Technologies u A technology is a process by which inputs are converted to an output. u E.g. labor, a computer, a projector,
Spanish Sentence Structure How can we make better sentences?
Overclipping It’s very important as a trader that you understand your clip size and what positions this allows you to have. In addition it will help you.
Subject pronoun chart Grammar essentials #9. Subject pronoun chart This is so important for the foundation of conjugating all the verbs in Spanish. There.
El presente indicativo ESPAÑOL 1. A. What is the present tense? It is when the action of a verb occurs at the moment. Verbs can be divided into two categories:
ALC 65 Hoy es viernes el 16 de marzo de 2012 Conjugate to eat (comer) Today is a test on foods, verbs, likes It will begin at 11:32 as a ppt show.
La Tarea para jueves, el primero de octubre de 2013: (Homework for Thursday...) Prepare for a mini-quiz on all the uses of TENER you see on these slides,
100 Book Challenge Desafío de leer 100 libros. Cada niño tendrán: Una bolsa de libros Una carpeta 2 libros para leer cada noche Un informe de lectura.
Español 2 lunes el 21 de septiembre Daily Warm Up (pick up a new sheet) Test Review Activities: – Pizzaras Blancas (white boards) – SINGO – Toca las estrellas.
¿Cuánto tiempo hace que…? You can ask when something happened in Spanish by using: ¿Cuándo + [preterit verb]…? ¿Cuándo llegaste a la clínica? When did.
EQUILIBRIUM OF A PARTICLE IN 2-D Today’s Objectives: Students will be able to : a) Draw a free body diagram (FBD), and, b) Apply equations of equilibrium.
Cómo trabajar con aplicaciones de Google
PALABRAS INTERROGATIVAS
Para conectarse a Internet
Welcome to Jeopardy!.
Quasimodo: Get ready for your quiz!.
-go Verbs There is a small but very important group of verbs that we call the “-go” verbs. These verbs are: Hacer: to make/do Poner: to put Salir:
My Spanish 2 classes are 2nd and 3rd periods
Lo esencial de Internet
Double Object Pronouns
PREGUNTAS: Questions and Question Words
El imperfecto Los verbos -AR Ch. 3 - Imperfect -AR Verbs.
POSSESSIVE ADJECTIVES
Base de Datos II Almacenamiento.
Lección 29 para el 6 y 7 de abril
Español 2 5 de diciembre de 2016
First Grade Dual High Frequency Words
La Tarea para martes, el 8 de octubre de 2013: (Homework for Tuesday...) Since we had no time for the mini-quiz on all the uses of TENER, today, use the.
More sentences that contain if…
Warm-up Fill in the blank with the correct form of the verb “ser” for each subject (p. 35): 1. Yo _______________ de Savannah. 2. Mis amigas ________.
Regular -AR Verbs Pág. 100.
Use this slide to revise the food items. There is no colour coding now, so be sure to emphasise the correct articles – un, una, unas.
Verb Conjugation IN PRETERITE TENSE Continued….
Cuentos Érase una vez 1.
El Presente Continuo When? How? Examples Irregulars.
Page 86 Realidades 2 Ser Vs. Estar.
Si (If) clauses describe a condition or event upon which another condition or event depends. Sentences with si clauses consist of a si clause and a main.
PREGUNTAS: Questions and Question Words
Los números.
Recetas 3 Objetivo: Hacer preguntas Hablar sobre la comida
Quasimodo: Tienes que hacer parte D de la tarea..
voy vas va van vamos vais
Vamonos Write a full sentence for each class, including one thing that you would need for that class. Ex. Math → Para la clase de matemáticas yo necesito.
JKSimMet Software (windows & buttons) Split Engineering Chile Ltda. General Salvo #331 oficina 201 Casilla Sucursal Panorámico Providencia – Santiago,
¡BIENVENIDOS AL ESPAÑOL 1!
Regular -AR Verbs Pág. 100.
ANTE TODO In Lección 13, you learned that the subjunctive is used in adverbial clauses after certain conjunctions. You will now learn how the subjunctive.
Directions (The directions are based on the fact that you would delete this slide before you save it to the student directory. Therefore slide 2 will become.
Irregular Preterite IR and SER
Antes de empezar In English, write 5 things you would like to do when you finish High School. 1) 2) 3) 4) 5)
Development of the concert programme
El agua.
Juliana Carmona Esteban Cano
Quasimodo: What do you remember about Direct Objects from last chapter? What do you remember about Indirect Objects from English classes you’ve taken before?
Antes de empezar contesta las preguntas sólo escribe las respuestas
Welcome to PowerPoint gdskcgdskfcbskjc. Designer helps you get your point across PowerPoint Designer suggests professional designs for your presentation,
Regular –ar (present tense)
Astronomy has really big numbers. Distance between Earth and Sun meters kilometers This is the closest star.
1. Anita managed to study her Spanish with Gina 3 days ago.
How much? - How many? English Grammar. When we want to know the quantity or amount of something, we ask questions starting with How much and How many.
Transcripción de la presentación:

Resumen de los elementos de Programación (Software) EX2000

Excitador Digital Campo del Generador A Núcleo de Control PCM D EX2000 Feedback Variables and Addressing   1)     Explain the overview drawing, The AC input is the secondary of the PPT, the SCR represents a PCM, the output of the SCR represents the output of the PCM to the generator field, the inputs on the left of the are all the feedback signals going into the EX2000. The box represents the control core of the exciter. Basically the feedback signals go into the control core, the core calculates the correct SCR firing angle and then outputs the firing signal to the PCM. 2)     With the use of mouse clicks the following will appear: a) What is the feedback to the Automatic Voltage regulator? (Generator Terminal Volts) b) What are the other 4 feedback signals? 1) AC Stator Amps 2) DC Field Volts 3) DC Field Amps 4) AC Line volts c) What needs to happen to the signals so that the control core can process the signals? (A to D and D to A) d) Rated Generator terminal volts = _______________ (Fill in the correct amount on the board) e) Equals ________________ counts (At this time explain that counts are units and 20,000 was chosen to represent rated voltage values, then click and 20,000 will appear in the space) f) At variable address VAR. ________________ (Now explain how the counts are stored at an address and what a variable address is, then click and VAR.1150 will appear) g) What would be the digital counts in VAR.1150 if the generator terminal voltage was 90% of rated (18000 counts) Tensión nominal de los terminales del Generador = ___________VAC Igual ___________Cuentas @ Dirección Variable VAR._____________ Cual seria la cuenta digital en VAR.1150 si la tensión del terminal del generador fuese un 90% de la nominal? PPT Secundario

Excitador Digital Campo del Generador A Núcleo de Control PCM D Tensión de la Terminal del Generador Amperios del Estator CA A D Núcleo de Control Tensión del Campo de CC Amperios del Campo de CC PCM Tensión de la Línea de CA EX2000 Feedback Variables and Addressing   This slide is similar to the last slide. Mouse clicks will bring up questions and answers. Remember the following: a) Rated AC Stator Amps is the value on the nameplate called ARMATURE AMPS b) DC Field volts is the maximum output of the PCM. That is referred to as having all the Scr’s getting turned on as soon as possible so that they are responding as if they were diodes. That would be called the v. Another name , used in the book as well as Edo is the ceiling voltage of the bridge. In either case the maximum voltage of the PCM is 1.35 X PPT secondary output in RMS. An example would be if the PPT is rated 4160/380 the max output of the bridge is 380 X 1.35 = 513 VDC c) DC field Amps is AFFL which is the nameplate value called FIELD AMPS d) AC line volts is refering to the PPT secondary voltage. This is scaled to the peak voltage. Therefore for a 380VAC secondary 20000 counts = 1.414 X 380VAC = 537VAC peak Amperios nominal del Estator de CA = ___________ Amps CA Igual ___________Cuentas @ Dirección Variable VAR._____________ PPT Secundario

Excitador Digital Campo del Generador A Núcleo de Control PCM D Tensión de la Terminal del Generador Amperios del Estator CA A D Núcleo de Control Tensión del Campo de CC Amperios del Campo de CC PCM Tensión de la Línea de CA EX2000 Feedback Variables and Addressing   This slide is similar to the last slide. Mouse clicks will bring up questions and answers. Remember the following: a) Rated AC Stator Amps is the value on the nameplate called ARMATURE AMPS b) DC Field volts is the maximum output of the PCM. That is referred to as having all the Scr’s getting turned on as soon as possible so that they are responding as if they were diodes. That would be called the v. Another name , used in the book as well as Edo is the ceiling voltage of the bridge. In either case the maximum voltage of the PCM is 1.35 X PPT secondary output in RMS. An example would be if the PPT is rated 4160/380 the max output of the bridge is 380 X 1.35 = 513 VDC c) DC field Amps is AFFL which is the nameplate value called FIELD AMPS d) AC line volts is refering to the PPT secondary voltage. This is scaled to the peak voltage. Therefore for a 380VAC secondary 20000 counts = 1.414 X 380VAC = 537VAC peak Tension Maxima del Campo de CC (Edo) = ___________VDC Igual ___________Cuentas @ Dirección Variable VAR._____________ PPT Secundario

Excitador Digital Campo del Generador A Núcleo de Control PCM D Tensión de la Terminal del Generador Amperios del Estator CA A D Núcleo de Control Tensión del Campo de CC Amperios del Campo de CC PCM Tensión de la Línea de CA EX2000 Feedback Variables and Addressing   This slide is similar to the last slide. Mouse clicks will bring up questions and answers. Remember the following: a) Rated AC Stator Amps is the value on the nameplate called ARMATURE AMPS b) DC Field volts is the maximum output of the PCM. That is referred to as having all the Scr’s getting turned on as soon as possible so that they are responding as if they were diodes. That would be called the v. Another name , used in the book as well as Edo is the ceiling voltage of the bridge. In either case the maximum voltage of the PCM is 1.35 X PPT secondary output in RMS. An example would be if the PPT is rated 4160/380 the max output of the bridge is 380 X 1.35 = 513 VDC c) DC field Amps is AFFL which is the nameplate value called FIELD AMPS d) AC line volts is refering to the PPT secondary voltage. This is scaled to the peak voltage. Therefore for a 380VAC secondary 20000 counts = 1.414 X 380VAC = 537VAC peak Amperios Nominal del Campo de CC = ___________DC Amps Igual ___________Cuentas @ Dirección Variable VAR._____________ PPT Secundario

Excitador Digital Campo del Generador A Núcleo de Control PCM D Tensión de la Terminal del Generador Amperios del Estator CA A D Núcleo de Control Tensión del Campo de CC Amperios del Campo de CC PCM Tensión de la Línea de CA EX2000 Feedback Variables and Addressing   This slide is similar to the last slide. Mouse clicks will bring up questions and answers. Remember the following: a) Rated AC Stator Amps is the value on the nameplate called ARMATURE AMPS b) DC Field volts is the maximum output of the PCM. That is referred to as having all the Scr’s getting turned on as soon as possible so that they are responding as if they were diodes. That would be called the v. Another name , used in the book as well as Edo is the ceiling voltage of the bridge. In either case the maximum voltage of the PCM is 1.35 X PPT secondary output in RMS. An example would be if the PPT is rated 4160/380 the max output of the bridge is 380 X 1.35 = 513 VDC c) DC field Amps is AFFL which is the nameplate value called FIELD AMPS d) AC line volts is refering to the PPT secondary voltage. This is scaled to the peak voltage. Therefore for a 380VAC secondary 20000 counts = 1.414 X 380VAC = 537VAC peak Tensión de Pico Nominal de la línea de CA = ___________AC Volts Igual ___________Cuentas @ Dirección Variable VAR._____________ PPT Secundario

Excitador Digital Campo del Generador A Núcleo de Control PCM D Tensión de la Terminal del Generador Amperios del Estator CA A D Núcleo de Control Tensión del Campo de CC Amperios del Campo de CC PCM Tensión de la Línea de CA EX2000 Feedback Variables and Addressing   This slide is similar to the last slide. Mouse clicks will bring up questions and answers. Remember the following: a) Rated AC Stator Amps is the value on the nameplate called ARMATURE AMPS b) DC Field volts is the maximum output of the PCM. That is referred to as having all the Scr’s getting turned on as soon as possible so that they are responding as if they were diodes. That would be called the v. Another name , used in the book as well as Edo is the ceiling voltage of the bridge. In either case the maximum voltage of the PCM is 1.35 X PPT secondary output in RMS. An example would be if the PPT is rated 4160/380 the max output of the bridge is 380 X 1.35 = 513 VDC c) DC field Amps is AFFL which is the nameplate value called FIELD AMPS d) AC line volts is refering to the PPT secondary voltage. This is scaled to the peak voltage. Therefore for a 380VAC secondary 20000 counts = 1.414 X 380VAC = 537VAC peak Cual es la dirección para la frecuencia del generador y que valor de cuentas representa la frecuencia nominal? Refiérase a GEH 6121 Anexo E PPT Secundario

Regulador Automático de Tensión Rotor + - 5PL A PCM D 1-6 FPL 2PL A 100% I 97% 3PL PT's D A ARCPL JKK CT's MK 5(6) OC 2000

Regulador Manual de Tensión

Programador EX2000

Programador Localmente opera cierta funciones asociadas con el Núcleo. Hace la misma función de la caja de herramienta “Toolbox”. Cambios hecho son instantáneos. Fallas Diagnosticadas son indicadas aquí. Tiene Rearme Blando “Soft Reset”. A S 100% I 99%

Estructura de la Programación EX2000

Automático y En-Línea A S 100% I 99%

“Default” y Parado de la unidad A S 97% I 0%

Mostrando Información 3 Tipos de direcciones pueden ser mostradas des del programador: Constantes (EE. xxxx ) Variables (VAR. xxxx ) Fallas (FLT. xxxx ) A S 100% I 99%

Mostrando Constantes (EE. xxxx ) Direcciones de Constante siempre comienzan con EE. xxxx. Para ver una dirección de Constante: SET DRV 7 (8) ENTER xxxx (ex: Numero de la Dirección “86”) El contenido de las direcciones pueden ser mostrados en Cuentas en conjunto con el nombre de las direcciones. EREG 500 Parameter_M Mode

Cambiando una Constante (EE. xxxx ) Desde el programador: Entre el valor nuevo (750) ENTER (Ejecución Instantánea!) o El valor nuevo puede ser insertado usando los pulsadores INC o DEC. EREG 750

Mostrando Variables (VAR. xxxx ) Los siguientes tres pasos tienen que ser hechos en orden para ver la variable.

Mostrando Variables (VAR. xxxx ) Imagínate que usted tiene información en un disco de computadora que le gustaría ver. Para ver la información usted necesitaría: Tener una Computadora Conseguir el Disco que desea ver Usar una lente de aumento para ver la información

Mostrando Variables (VAR. xxxx ) Step 1# Desde el programador: SET DRV 7 (8) ENTER Entre usando el teclado 110, 111, 112, o 113 ENTER (DIAG xxxx ) Hay 4 Registradoras (computadoras) Disponible para su uso. Son llamadas 110, 111, 112, y 113. Use cualquiera que este disponible. Parameter_M Mode DIAG (xxxx) Register # 110

Mostrando Variables (VAR. xxxx ) Step 2# Inserte el Numero de la dirección variable (por ejemplo: 1150) que usted desee ver. ENTER El disco representa cualquier dirección variable que usted desee ver. Cualquier Dirección Variable VAR. xxxx

Mostrando Variables (VAR. xxxx ) Step 3# Parameter_M Mode CLEAR TEST 31 ENTER TEST 31 es una Herramienta de Diagnostico que le permite el acceso a cualquiera de los 4 registros. Diagnostic Mode 1.2 xxxx yyyyy TEST 31

Mostrando Variables (VAR. xxxx ) El mostrador final le enseñara el contenido de 2 variables diferentes en 2 registros diferentes. 1.2 significa: 1 – 110 (20000 cuentas) 2 – 111 (5000 cuentas) 1.2 20000 5000

Mostrando Variables (VAR. xxxx ) Pulsee INC o DEC para ver el contenido en los registros 3.4: 3 – 112 (500 Cuentas) 4 – 113 (En Blanco- nada esta cargado en el registro) Variables permanecerán en los Registros hasta una de dos cosas ocurran: Perdida de carga al excitador Una variable por otra variable. 3.4 500

Que Direcciones están en el registrador? La Dirección de las variable que están cargadas en cualquier registro pueden ser fácilmente determinadas: SET DRV 7 (8) ENTER Entre usando el teclado (una a la vez) 110 (Registro 1) 111 (Registro 2) 112 (Registro 3) 113 (Registro 4) ENTER (Despliega el nombre de la variable y la dirección). EXVMAG 1150 Parameter_M Mode

Condiciones de Falla FLT.377 MCP_WDOG 9 tipos de Fallas Diagnosticadas (GEH 6121, Ch: 8). Una Falla Diagnosticada es indicada cuando el despliegue destella: FLT. – Fallo 377 – Numero Especifico del Fallo MCP_WDOG – Nombre del fallo Una guia es dada en GEH 6121, Table 8-4 o en la Caja de Herramienta “Toolbox” de que exactamente la falla es y que acciones tomar. FLT.377 MCP_WDOG

Bloques del Software del EX2000 (GEH 6121 Ch:3)

Limites de Baja Excitación (UEL)