Descargar la presentación
La descarga está en progreso. Por favor, espere
Publicada porJulio Alberto Guerrero Enriquez Modificado hace 5 años
1
Siemens presenta SINAMICS G120 El variador modular, eficiente y robusto.
2
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 2December 18, 2019 Esquema del Convertidor Frecuencia ETAPA DE POTENCIA ETAPA DE CONTROL MC: U/F, VECTOR HMI
3
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 3December 18, 2019 Tipos de cargas industriales *) Source: Energie Agentur NRW (2010) Normalmente requieren un sobre esfuerzo para el arranque o durante alguna etapa del proceso Torque constante 100% Torque Velocidad Torque Velocidad 100% Torque variable 100% Torque Velocidad 100% 80 50 La fuerza necesaria para mover la carga es por lo general estandar
4
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 4December 18, 2019 Mantenimiento35Mantenimiento35 Funciones31Funciones31 Puesta en marcha27Puesta en marcha27 Integración24Integración24 Fácil manejo17Fácil manejo17 Robustez13Robustez13 Eficiencia energética6Eficiencia energética6 Modularidad4Modularidad4 Overview2Overview2 SINAMICS G120 Referencias 35Referencias 35 Anexos35Anexos35
5
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 5December 18, 2019 SINAMICS G120 – el variador modular Eficiencia energética, ahorro y robustez Modularidad Reducción de inventario. Fácil y rápido diagnostico y reemplazo. Modularidad Reducción de inventario. Fácil y rápido diagnostico y reemplazo. + Fácil de manejo Puesta en marcha y diagnostico. Fácil de manejo Puesta en marcha y diagnostico. + Tecnología Safety integrado, tareas de posicionamiento, funciones de PLC y más. Tecnología Safety integrado, tareas de posicionamiento, funciones de PLC y más. + Integración Full integración a TIA Portal y a sistemas de terceros Integración Full integración a TIA Portal y a sistemas de terceros + Eficiencia energética PROFIenergy, recuperación de la energía y mas Eficiencia energética PROFIenergy, recuperación de la energía y mas + Robustez Robustez en el operación y en el tiempo de vida. Robustez Robustez en el operación y en el tiempo de vida. +
6
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 6December 18, 2019 Mantenimiento35Mantenimiento35 Funciones31Funciones31 Puesta en marcha27Puesta en marcha27 Integración24Integración24 Fácil manejo17Fácil manejo17 Robustez13Robustez13 Eficiencia energética6Eficiencia energética6 Modularidad4Modularidad4 Overview2Overview2 SINAMICS G120 Referencias 35Referencias 35 Anexos35Anexos35
7
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 7December 18, 2019 SINAMICS G120 Modularidad Sobretensión Cortocircuito Falla a tierra Armónicos ALMACEN
8
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 8December 18, 2019 Mantenimiento35Mantenimiento35 Funciones31Funciones31 Puesta en marcha27Puesta en marcha27 Integración24Integración24 Fácil manejo17Fácil manejo17 Robustez13Robustez13 Eficiencia energética6Eficiencia energética6 Modularidad4Modularidad4 Overview2Overview2 SINAMICS G120 Referencias 35Referencias 35 Anexos35Anexos35
9
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 9December 18, 2019 SINAMICS G120 PROFIenergy Consulting/ Know-how Software Functions Hardware DesignPlanningEngineeringExecutionServices The challenge: Provide energy-related data for the system components to create transparency for the energy management system using standardized access routes; energy saving by specifically shutting down the plant/system and/or sections of it The solution: Use the existing communication infrastructure of the PROFINET bus system together with the PROFIenergy profile to provide energy data The higher-level control specifically shuts down the plant or system during non-operational times Customer advantages: Distributed units are brought into a state that is the most favorable from an energy perspective Transparency about the various loads and consumers Machining time Idle time Main drive Auxiliary systems Energy saving potential: G120D/ G120 S120 Chassis S120 Booksize S120 Cabinet / S150 S120 Booksize Compact G120P G130/ G150 G120C Energy usage without PROFIenergy Energy usage with PROFIenergy Controller SIMATIC ET 200S Hydraulic press Sensor 1Sensor 2Actuator 1 Actuator 2 SIMATIC ET 200S Hydraulic press Sensor 1Sensor 2Actuator 1 Actuator 2 PROFINET Industrial Ethernet SIMATIC S7-400/300 S1 S2 A1 A2 On Off On Off On Start break Stop break Sensors actuators Off Hydraulic press Short break Long break
10
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 10December 18, 2019 Consulting/ Know-how Software Functions Hardware DesignPlanningEngineeringExecutionServices Machining time Idle time Main drive Auxiliary systems Energy saving potential: El Reto: Maquinas con bajo torque y con una dinámica baja no requieren altos niveles de torque en todo su rango de operación. La solución: Los variadores Sinamics G120, en modo de operación ECO con control U/F recude las perdidas en el motor debido a la automática adaptación del flujo del campo magnético. Ventajas para el usuario: Bajo consumo de energía conla maquina a velocidad estable en un rabgo de carga parcial. Reducción de las perdidas del motor Alta precisión como resultado de una transferencia térmica dentro de la maquina. SINAMICS G120 Modo ECO / automatica reducción del flujo para el motor de inducción G120 G120C G120P G130/ G150 S120 Compact, Booksize, Chassis S110 S120 COMBI S120/ S150 Cabinet G120D El modo ECO es desactivado por los cambios del setpoint o por una tensión de salida fuera del rango de tolerancia SIMOTICS Niederspannungsmotoren Modo ECO en operación U/F Energy saving Torque-generating current Flux-generating current Rated magnetizing current Lower magnetizing current 3
11
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 11December 18, 2019 Consulting/ Know-how Software Functions Hardware DesignPlanningEngineeringExecutionServices SINAMICS G120 Modo Hibernación The challenge: Efficient operation of pumps/fans/compressors (PFC) in the partial load range and field weakening operation – and for significantly fluctuating pressure/flow demands The solution: The integration of pressure/flow rate storage devices in the system avoids partial and weak load operation In non-operational periods, the drive train is completely shut down (hibernation mode) In the operating phases, the drive train always operates at the optimum operating point Customer advantages: Reduced energy consumption Reduced wear and increased service life of the mechanical components Machining time Idle time Main drive Auxiliary systems Energy saving potential: SINAMICS G120P IP54 Line SIMOTICS GP / SD 100% t n t n Without hibernation mode With hibernation mode G120 with CU230P-2 G120P Buffer storage device
12
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 12December 18, 2019 Consulting/ Know-how Software Functions Hardware DesignPlanningEngineeringExecutionServices The challenge: Complex mechanical pumps are required for pump systems with closed-loop control of the flow rate Frequent service means shutting down and reducing the overall system availability Pressure surges ("water hammer") reduce the service life of pumps The solution: SINAMICS in conjunction with up to three SIRIUS motor starters with more basic pumps for regulating the volume flow by configuring a cascade system based on motor starters and energy-efficient fine regulation using a converter Two drives combined for applications demanding a higher dynamic performance Customer advantages: Lower costs for the solution Higher degree of reliability through redundancy Lower pump complexity Closed-loop flow control without valve losses Machining time Idle time Main drive Auxiliary systems Energy saving potential: SINAMICS G120 Arranque en cascada G180 G120P G130/ G150 G120 with CU230P-2 S120 Chassis/ Cabinet S150 Cabinet SIRIUS 3RW44 soft starter Compressor 33 kW Base load Compressor 33 kW Base load Compressor 33 kW Base load Compressor 33 kW Base load Compressor 33 kW Base load Compressor 0–33 kW controllable Compressor 33 kW Base load 06:00 h12:00 h15:00 h 33% 66% 100% Power SIRIUS soft starter SINAMICS GSIRIUS soft starter Please click on the image to animate it! SIMOTICS low-voltage motors
13
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 13December 18, 2019 Consulting/ Know-how Software Functions Hardware DesignPlanningEngineeringExecutionServices The challenge: If induction motors connected to a converter are frequently operated in the rated motor speed range, then unnecessary losses are incurred The solution: When the rated motor speed is reached, the converter automatically switches the connected IE2, IE3 induction motors directly to the line supply Customer advantages: Converter losses and additional motor losses through converter operation are eliminated If the converter develops a fault, the motor can be switched over to essential service operation Machining time Idle time Main drive Auxiliary systems Energy saving potential: SINAMICS G120 Modo Bypass G180 S120 with CU310-2 CU320-2 G130/ G150 G120P SIRIUS 3RT2 contactor S120 Chassis/ Cabinet G120 with CU230P-2 Line Relay outputs (digital outputs, DO) SINAMICS G120P IP20 SIMOTICS GP / SD Interlocking against simultaneous closure SIRIUS
14
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 14December 18, 2019 Consulting/ Know-how Software Functions Hardware DesignPlanningEngineeringExecutionServices The challenge: Output of the energy usage values or the energy saved during operation. The solution: In operation, SINAMICS converters output the actual energy usage value or, using an energy saving counter, the saved energy cumulated over the operating hours in comparison to a fixed- speed application. Customer advantages: Transparency of the energy usage/savings in operation Actual active power values Machining time Idle time Main drive Auxiliary systems Energy saving potential: SINAMICS G120 Consumo de energía / contador de ahorro de energía S150 Cabinet S120 Compact, Booksize, Chassis S120 Cabinet G120 G120C G120P G110 G130/ G150 G120D Actual active power measured values Cumulative balance of the output energy ( the energy drawn minus the energy fed back into the line supply) Energy saving counter for fluid-flow machines
15
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 15December 18, 2019 Mantenimiento35Mantenimiento35 Funciones31Funciones31 Puesta en marcha27Puesta en marcha27 Integración24Integración24 Fácil manejo17Fácil manejo17 Robustez13Robustez13 Eficiencia energética6Eficiencia energética6 Modularidad4Modularidad4 Overview2Overview2 SINAMICS G120 Referencias 35Referencias 35 Anexos35Anexos35
16
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 16December 18, 2019 SINAMICS G120 Robustez Incrementa la robustez y mejora la calidad Concepto ventilador optimizado Ventilación silenciosa en el disipador y solo cuando es necesario Reactancia en el bus DC Diseño robusto como resultado de la reactancia en el bus DC(adaptado para operación en redes inestables) Menos espacio requerido en el gabinete Diseño compacto (alta densidad de potencia), montaje lado a lado y tipo push trought Para ambientes agresivos Grado de protección hasta IP21:; Temperatura de operación -20 hasta 60°C: 50°C como High Overload Uso en ambientes extremos Tarjetas resistentes según conformal coating 3C2 como estándar Versiones de voltaje 200…240V: De 0.75 a 75HP, 380…480V: De 0.5 a 400HP, 500…690V: De 10 a 125HP Longitud de cable del motor Sin reactancia Apantallado: 300m Sin pantalla: 450m Aplicado para bombas sumergibles
17
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 17December 18, 2019 SINAMICS G120 Reactancia en el bus DC Reactancia ACReactancia DC Reducción de los armonicos Las reactancias estándares tienen una tensión de cortocircuito de u k = 2% La reactancia DC tiene una tensión de u k = 3% La 5th armónica es mejor atenuada Tension de salida del convertidor Caída de tensión 2% Caída de tensión de 1% Alto voltaje en el bus DC=> alto voltaje de salida Requerimientos de espacio Se debe considerar espacio en el tablero Integrado óptimamente en el convertidor Incrementa el peso del convertidor Protección del rectificador contra sobretensiones Reactancia AC es suficiente Diseño de hardware mejorado Diodos con alta resistencia a sobretensiones, varistores y capacitores contra protección de caídas transitorias y notches DC choke vs. AC choke 12/18/2019Page 17DF MC GMC MP1
18
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 18December 18, 2019 SINAMICS G120 Robustez: Temperatura / IEC 60721-3-3
19
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 19December 18, 2019 SINAMICS G120: Puesta en marcha con BOP
20
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 20December 18, 2019 SINAMICS G120 Fácil manejo: PANEL DE CONTROL BOP
21
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 21December 18, 2019 SINAMICS G120 Fácil manejo: PANEL DE CONTROL BOP ESTRUCTURA DEL MENU BOP
22
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 22December 18, 2019 SINAMICS G120 Puesta en marcha
23
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 23December 18, 2019 SINAMICS G120 Puesta en marcha
24
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 24December 18, 2019 SINAMICS G120 Puesta en marcha
25
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 25December 18, 2019 SINAMICS G120 Puesta en marcha
26
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 26December 18, 2019 SINAMICS G120 Puesta en marcha
27
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 27December 18, 2019 SINAMICS G120 Macros
28
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 28December 18, 2019 SINAMICS G120 Macros
29
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 29December 18, 2019 SINAMICS G120 Macros
30
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 30December 18, 2019 SINAMICS G120 Macros
31
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 31December 18, 2019 SINAMICS G120 Macros
32
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 32December 18, 2019 SINAMICS G120 Macros
33
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 33December 18, 2019 SINAMICS G120 Puesta en marcha
34
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 34December 18, 2019 SINAMICS G120 Puesta en marcha
35
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 35December 18, 2019 SINAMICS G120 Puesta en marcha
36
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 36December 18, 2019 SINAMICS G120 Puesta en marcha
37
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 37December 18, 2019 SINAMICS G120 Puesta en marcha
38
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 38December 18, 2019 SINAMICS G120 Puesta en marcha
39
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 39December 18, 2019 SINAMICS G120 Puesta en marcha
40
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 40December 18, 2019 SINAMICS G120: Puesta en marcha con IOP-2
41
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 41December 18, 2019 SINAMICS G120 Puesta en marcha
42
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 42December 18, 2019 SINAMICS G120 Puesta en marcha: Estructura del Menú
43
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 43December 18, 2019 SINAMICS G120 Puesta en marcha: Modo manual personalizado
44
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 44December 18, 2019 SINAMICS G120 Puesta en marcha: Inhabilitación de botón HAND/AUTO
45
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 45December 18, 2019 SINAMICS G120 Puesta en marcha: Renombrar backups
46
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 46December 18, 2019 SINAMICS G120 Puesta en marcha: Renombrar desde la PC
47
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 47December 18, 2019 SINAMICS G120 Puesta en marcha: Extras, Presentación de los datos en el display
48
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 48December 18, 2019 SINAMICS G120 Puesta en marcha: Gráficos de tendencias With a long press of the INFO button, the graph data is written to a Trend information file on the IOP-2.
49
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 49December 18, 2019 DatumPage 49 SINAMICS G120 Fácil manejo: PANEL DE CONTROL IOP-2 Feature / FunctionBenefit Simple configuration of the Fieldbus interface (Ethernet) -Fast configuration without expert knowledge. -Fast overview about all active settings. User is able to select directly the attribute which he will configure. -the device name can be easily changed by IOP-2. Powerful Service & Support functionality -Easy access to product information of the current drive system (Power Module, Control Unit, IOP-2) via mobile devices. -Allows an easy and fast contact to customer support. -High flexibility in use of any standard code scanner. The highest comfort is available by using the Siemens Industry Online Support App.
50
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 50December 18, 2019 SINAMICS G120: Puesta en marcha con Startdrive
51
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 51December 18, 2019 Mantenimiento35Mantenimiento35 Funciones45Funciones45 integración42integración42 Puesta en marcha24Puesta en marcha24 Fácil manejo17Fácil manejo17 Robustez13Robustez13 Eficiencia energética6Eficiencia energética6 Modularidad4Modularidad4 Overview2Overview2 SINAMICS G120 Referencias 35Referencias 35 Anexos35Anexos35
52
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 52December 18, 2019 SOFTWARE DE CONFIGURACION - STARTER
53
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 53December 18, 2019 Maleta demostrativa – Velocidades Fijas (4 o 16) CONSIGNA PRINCIPAL P1070 = 1024
54
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 54December 18, 2019 Maleta demostrativa – Frecuencia maxima FRECUENCIA O VELOCIDAD PARAMETRO VELOCIDAD MAXIMAP1082 ESCALAMIENTO Y1P0758 Y2P0760 X1P0757 X2P0759
55
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 55December 18, 2019 Maleta demostrativa – Memorización potenciómetro motorizado FRECUENCIA O VELOCIDAD PARAMETRO VELOCIDAD MAXIMAP1030[ ]
56
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 56December 18, 2019 Maleta demostrativa – Marcha atrás deshabilitada Prohíbe la inversión de giro, para el caso de bombas y ventiladores PARAMETRO BLOQUEAR SENTIDO DE GIROP1110
57
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 57December 18, 2019 Maleta demostrativa – Parada Natural o Parada en rueda libre PARADA NATURAL P0844 (No parada natural/ parada natural OFF2) = R0722.3 (entrada digital 3) ON / PARADA NATURAL con 1 entrada digital P0840 (ON/OFF1) = R052.4 (parada natural activa OFF2) P0844 (No parada natural/ parada natural OFF2) = R0722.0 (entrada digital 0)
58
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 58December 18, 2019 Maleta demostrativa – Rearranque al vuelo Permite volver a conectar un motor en movimiento. Por ejemplo cuando hay pequeños cortes en la red o cuando se quiere arrancar un motor que es arrastrado por la carga. PARAMETRO REARRANQUE AL VUELOP1200 PARAMETRO REARRANQUE AUTOMATICO P1210
59
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 59December 18, 2019 Maleta demostrativa – Secuencia de fase invertida Permite invertir las fases del motor sin necesidad de cambiar el cableado físico PARAMETRO SECUENCIA DE FASESP1820
60
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 60December 18, 2019 Maleta demostrativa – Aumento de torque en el arranque Permite elevar la tensión de arranque para obtener un mayor par de arranque PARAMETRO ELEVACION PERMANENTE DE LA TENSION P1310 AUMENTO TENSION EN ACELERACION P1311 AUMENTO DE TENSION EN ARRANQUEP1312
61
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 61December 18, 2019 BLOQUES DE FUNCIONES LIBRES (PLC)
62
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 62December 18, 2019 BLOQUES DE FUNCIONES LIBRES (PLC)
63
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 63December 18, 2019 Maleta demostrativa – BLOQUES DE FUNCIONES LIBRES (PLC) R722.0 DI0 P840 ON/OFF1 12 SEG 4 SEG
64
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 64December 18, 2019 ALARMAS, FALLAS y AVISOS DEL SISTEMA
65
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 65December 18, 2019 ALARMAS, FALLAS y AVISOS DEL SISTEMA ALARMAS:Axxxxx 8 ALARMAS ACTUALES 56 EN EL HISTORIAL FALLOS:Fxxxxx 8 FALLOS ACTUALES 56 EN EL HISTORIAL
66
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 66December 18, 2019 FALLOS COMUNES
67
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 67December 18, 2019 FALLOS COMUNES
68
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 68December 18, 2019 FALLOS COMUNES
69
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 69December 18, 2019 FALLOS COMUNES
70
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 70December 18, 2019 FALLOS COMUNES
71
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 71December 18, 2019 FALLOS COMUNES
72
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 72December 18, 2019 FALLOS COMUNES
73
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 73December 18, 2019 Mantenimiento67Mantenimiento67 Funciones45Funciones45 integración42integración42 Puesta en marcha24Puesta en marcha24 Fácil manejo17Fácil manejo17 Robustez13Robustez13 Eficiencia energética6Eficiencia energética6 Modularidad4Modularidad4 Overview2Overview2 SINAMICS G120 Referencias 35Referencias 35 Anexos35Anexos35
74
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 74December 18, 2019 MANTENIMIENTO Recomendaciones de rutina: Limpieza de filtros del gabinete periódicamente Ajuste de los terminales de fuerza del variador Limpieza de suciedad externa con aspiradora o brocha de los elementos de control Limpieza del disipador Funcionamiento del ventilador Experto: Verificación de los condensadores Verificación de los diodos e IGBT’s
75
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 75December 18, 2019 MANTENIMIENTO Cambio de ventilador Ajuste tiempo de mantenimiento al motor p0651 Intervalo de mantenimiento en horas del motor p0650 Horas de funcionamiento actuales del motor
76
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 76December 18, 2019 SINAMICS G120: Integracion con S7-1200
77
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 77December 18, 2019 Mantenimiento35Mantenimiento35 Funciones31Funciones31 integración42integración42 Puesta en marcha24Puesta en marcha24 Fácil manejo17Fácil manejo17 Robustez13Robustez13 Eficiencia energética6Eficiencia energética6 Modularidad4Modularidad4 Overview2Overview2 SINAMICS G120 Referencias 35Referencias 35 Anexos35Anexos35
78
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 78December 18, 2019 Integración – TIA PORTAL TIA Portal incorpora las últimas versiones de Software de Ingeniería SIMATIC STEP 7, WinCC y Startdrive para la planificación, programación y diagnóstico de todos los controladores SIMATIC, pantallas de visualización y accionamientos SINAMICS de última generación.
79
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 79December 18, 2019 Integración – Telegramas STW HSW ZSW HIW TELEGRAMA 1: 2 WORDS ENVIOS / 2 WORDS RECEPCION ENTRADA I SALIDA Q STW: Palabra de mando HSW: Valor de consigna ZSW: Palabra de estado HSW: Consigna real PZD QW256 QW257 QW258 QW259 IW256 IW257 IW258 IW259 CONTROL WORD 1514131211109876543210 STW BITVALORSIGNIFICADO 0 1010 ON OFF 1 1010 En servicio OFF 2 2 1010 En servicio OFF 3 3 1010 Desbloquear servicio Bloquear servicio 4 1010 En servicio Bloquear generador de rampa 5 1010 Desbloquear generador de rampa Parar generador de rampa 6 1010 Desbloquear valor de consigna Bloquear valor de consigna 7 1010 Acusar fallo Sin función 8 1010 Mando por impulsos derecha 9 1010 Mando por impulsos izquierda 10 1010 Valores de consigna validos Valores de consigna no validos 11 1010 Inversion de valor de consigna Sin inversion de valor de consigna 12 1010 13 1010 Potenciometro hacia arriba 14 1010 Potenciometro hacia abajo 15 1010 Mando directo BOP Mando a distancia
80
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 80December 18, 2019 Integración – PZD’s CONTROL WORD 1514131211109876543210 STW BYTE 1 QW 257 BYTE 0 QW 256 LISTO / STOP: 16#047E RUN / START : 16#047F INVERSION : 16#0C7F RESET : 16#04FE
81
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 81December 18, 2019 Integración – Escalamiento 0 HEX DEC 0 16#0000 016#4000 60 HZ 16384 0 100%
82
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 82December 18, 2019 Integración – CON OTRAS MARCAS SINAMICS G: Speed Control of a G120 with Allen-Bradley controller (Compact/ControlLogix with RSLogix 5000) via EtherNet/IP
83
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 83December 18, 2019 Mantenimiento67Mantenimiento67 Funciones45Funciones45 integración42integración42 Puesta en marcha24Puesta en marcha24 Fácil manejo17Fácil manejo17 Robustez13Robustez13 Eficiencia energética6Eficiencia energética6 Modularidad4Modularidad4 Overview2Overview2 SINAMICS G120 Referencias 70Referencias 70 Anexos75Anexos75
84
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 84December 18, 2019 Highlights Sinamics G120 Aplicación: Bombas centrifugas Cliente:Backus Arequipa 2 Sinamics G120 de 75HP
85
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 85December 18, 2019 Highlights Sinamics G120 Aplicación: Maquinas Cardado de lineas de hilandaria Cliente:Michell Arequipa 2 Sinamics G120 de 15HP
86
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 86December 18, 2019 Highlights Sinamics G120 Aplicación: Ventilador Centrifugo Cliente:O-I Peru 2 Sinamics G120 de 400HP
87
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 87December 18, 2019 Highlights Sinamics G120 Aplicación:Planta de Prensas harina de pescado Cliente:Copeinca 2 Sinamics G120 de 250HP
88
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 88December 18, 2019 Mantenimiento35Mantenimiento35 Funciones31Funciones31 Puesta en marcha27Puesta en marcha27 Integración24Integración24 Tecnología22Tecnología22 Fácil manejo20Fácil manejo20 Robustez16Robustez16 Eficiencia energetica10Eficiencia energetica10 Modularidad7Modularidad7 Overview3Overview3 SINAMICS G120 Anexos35Anexos35 Anexos35Anexos35 Anexos35Anexos35
89
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 89December 18, 2019 Positioning within the SINAMICS AC LV Product Family Component overview / technical ratings
90
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 90December 18, 2019 SINAMICS G120 Highlights Modularity for high efficiency
91
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 91December 18, 2019 INSTALACION ELECTRICA FUERZA
92
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 92December 18, 2019 INSTALACION ELECTRICA CONTROL
93
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 93December 18, 2019 INSTALACION ELECTRICA CONTROL ENTRADAS ANALOGICAS ENTRADAS DIGITALES
94
Motion Control & Low Voltage Drives SINAMICS G120 Overview Unrestricted © Siemens Industry, Inc. 2014 All rights reserved. Page 94December 18, 2019 Siemens Answers with SINAMICS G120 Modular Vector Drive Ivan Solorzano Zevallos Sales Specialist Siemens Digital Factory Av. Domingo Orue 971 Surquillo Phone: 997-505-330 E-mail: ivan.solorzano_zevallos@siemens.com ivan.solorzano_zevallos@siemens.com siemens.com/answers
Presentaciones similares